STAGING SITE - GO TO LIVE

The Fredericks Company
Televac
  • Products
    • Televac® Vacuum Gauges
    • Product Selection Guide
    • MX200 Online Order Hub
    • ETI Hot Ion Vacuum Gauges
    • Filaments
    • Vacuum Calibration & Service
    • ISO 17025 Accredited, NIST, Factory Calibration Overview
    • Request Calibration and Service
    • Calibration and Service Instructions
    • Vacuum Calibration Tolerances
    • Technical Support
    • Tilt Measurement
    • Product Selection Guide
    • ApexTwo™ Dual-Axis Inclinometer (New!)
    • What Is An Electrolytic Tilt Sensor?
  • Markets
    • Tilt Markets
    • Agricultural Vehicles
    • Construction Tools, Laser Leveling
    • Construction Vehicles
    • Geotechnical Monitoring and Structural Monitoring
    • Railway Monitoring
    • RV Leveling
    • Satellite Antenna Positioning
    • Televac® Vacuum Markets
    • E-Beam Welding
    • Freeze Dryers
    • Liquefied Natural Gas (LNG), Industrial Gas, Cryogenics
    • Medical Particle Accelerator
    • National Labs, Research and Development
    • Semiconductor
    • Thin Film Deposition
    • Vacuum Distillation
    • Vacuum Glove Boxes
    • Vacuum Furnace, Heat Treat
  • About Us
    • About Us
    • ISO Certification
    • ISO 9001:2015
    • ISO 17025:2017
    • Ordering Information
    • Customer Credit Application
    • How to Request a Quote Online
    • Terms and Conditions
    • Warranty Information
    • Frequently Asked Questions
  • Resources
    • Televac® Vacuum Resources
    • Documentation
    • 3D Models (STEP Files)
    • Product Selection Guide
    • MX200 Online Order Hub
    • Web Serial Terminal
    • Vacuum Measurement Converter
    • Vacuum Calibration & Service
    • ISO 17025 Accredited, NIST, Factory Calibration Overview
    • Request Calibration and Service
    • Calibration and Service Instructions
    • Vacuum Calibration Tolerances
    • Technical Support
    • Tilt Measurement Resources
    • Documentation
    • 3D Models (STEP Files)
    • Product Selection Guide
    • Web Serial Terminal
    • Angle Measurement Converter
    • Frequently Asked Questions
    • Employee Spotlight
    • Blog
  • Contact Us
    • Contact Us
    • Request a Quote
    • Customer Credit Application
    • How to Request a Quote Online
    • Vacuum Calibration & Service
    • ISO 17025 Accredited, NIST, Factory Calibration Overview
    • Request Calibration & Service
    • Calibration and Service Instructions
    • Technical Support
    • Find a Tilt Measurement Rep
    • Find a Televac® Rep
    • Careers
My Account
0
Cart
Search
My Account
0
Cart
SearchSearch
  • Products
    • Televac® Vacuum Gauges
    • Product Selection Guide
    • MX200 Online Order Hub
    • ETI Hot Ion Vacuum Gauges
    • Filaments
    • Vacuum Calibration & Service
    • ISO 17025 Accredited, NIST, Factory Calibration Overview
    • Request Calibration and Service
    • Calibration and Service Instructions
    • Vacuum Calibration Tolerances
    • Technical Support
    • Tilt Measurement
    • Product Selection Guide
    • ApexTwo™ Dual-Axis Inclinometer (New!)
    • What Is An Electrolytic Tilt Sensor?
  • Markets
    • Tilt Markets
    • Agricultural Vehicles
    • Construction Tools, Laser Leveling
    • Construction Vehicles
    • Geotechnical Monitoring and Structural Monitoring
    • Railway Monitoring
    • RV Leveling
    • Satellite Antenna Positioning
    • Televac® Vacuum Markets
    • E-Beam Welding
    • Freeze Dryers
    • Liquefied Natural Gas (LNG), Industrial Gas, Cryogenics
    • Medical Particle Accelerator
    • National Labs, Research and Development
    • Semiconductor
    • Thin Film Deposition
    • Vacuum Distillation
    • Vacuum Glove Boxes
    • Vacuum Furnace, Heat Treat
  • About Us
    • About Us
    • ISO Certification
    • ISO 9001:2015
    • ISO 17025:2017
    • Ordering Information
    • Customer Credit Application
    • How to Request a Quote Online
    • Terms and Conditions
    • Warranty Information
    • Frequently Asked Questions
  • Resources
    • Televac® Vacuum Resources
    • Documentation
    • 3D Models (STEP Files)
    • Product Selection Guide
    • MX200 Online Order Hub
    • Web Serial Terminal
    • Vacuum Measurement Converter
    • Vacuum Calibration & Service
    • ISO 17025 Accredited, NIST, Factory Calibration Overview
    • Request Calibration and Service
    • Calibration and Service Instructions
    • Vacuum Calibration Tolerances
    • Technical Support
    • Tilt Measurement Resources
    • Documentation
    • 3D Models (STEP Files)
    • Product Selection Guide
    • Web Serial Terminal
    • Angle Measurement Converter
    • Frequently Asked Questions
    • Employee Spotlight
    • Blog
  • Contact Us
    • Contact Us
    • Request a Quote
    • Customer Credit Application
    • How to Request a Quote Online
    • Vacuum Calibration & Service
    • ISO 17025 Accredited, NIST, Factory Calibration Overview
    • Request Calibration & Service
    • Calibration and Service Instructions
    • Technical Support
    • Find a Tilt Measurement Rep
    • Find a Televac® Rep
    • Careers
1F Diaphragm
1 - 7600 Torr
1E Diaphragm
1 - 1000 Torr
4A Convection
10-3 - 1000 Torr
MX4A Convection
10-4 - 1000 Torr
2A Thermocouple
10-3 - 20 Torr
MX2A Thermocouple
10-4 - 1000 Torr
CC-10 Wide Range
10-9 - 1000 Torr
7B Cold Cathode
10-7 - 10-3 Torr
MX7B Cold Cathode
10-8 - 10-3 Torr
MX7M Cold Cathode
10-11 - 10-2 Torr
7E Cold Cathode
10-8 - 10-2 Torr
7F/7FC/7FCS Cold Cathode
10-11 - 10-2 Torr
3F Mini BA Hot Ion
10-10 - 10-2 Torr
Shop Televac® Vacuum Gauges
Vacuum Controllers
  • Overview
  • MX200
  • MX200 PROFINET
  • MX200 EthernetIP
  • MV2A
  • Compact 2A
Portable Vacuum Controllers
  • Overview
  • VacuGuard™
  • B2A Portable
Active Vacuum Gauges
  • Overview
  • MX2A Thermocouple (Pirani)
  • MX4A Convection (Pirani)
  • MX7B Cold Cathode
  • MX7M Cold Cathode (New!)
  • MX Active Gauge EthernetIP Gateway
  • CC-10 Wide Range
Passive Vacuum Gauges
  • Overview
  • 2A Thermocouple (Pirani)
  • 2A VacuMini Thermocouple (Pirani)
  • 2A NASA Mini Thermocouple (Pirani)
  • 2V6 Thermocouple (Pirani)
  • 4A Convection (Pirani)
  • 1E Piezo Diaphragm
  • 7B Penning Magnetron Cold Cathode
  • 7E DI Magnetron Cold Cathode
  • 7F DI Magnetron Cold Cathode
  • 7FC DI Magnetron Cold Cathode
  • 7FCS DI Magnetron QS Cold Cathode
Capacitance Manometers
  • Overview
  • XacTorr® Series Capacitance Manometer
ETI Hot Ion Vacuum Gauges
  • Overview
  • Glass Bayard-Alpert Ion Gauge
  • Bayard-Alpert Ion Gauge
Filaments
  • Overview
  • VIC/Veeco Filaments
  • Custom Filaments
Accessories
  • Overview
  • MX200/MM200 Modules
  • Vacuum Gauge Baffle Filters
  • Sensor Simulators
  • Spare Parts
  • Cables
    • Overview
    • MX200 Cables
    • VacuGuard™, B2A Portable Cables
    • MV2A, Compact 2A Cables
    • MX2A, MX4A, MX7B, MX7M, CC-10 Cables
    • Legacy Cables (MM200, MC300, MP)
Vacuum Calibration Services
  • Overview
  • Calibration and Service Instructions
  • Request Calibration and Service
  • Vacuum Calibration Tolerances
  • Technical Support
Legacy Products
  • Overview
  • MC300
  • MM200
  • MP2AR Thermocouple
  • MP3DR Hot Ion
  • MP4AR Convection
  • MP7ER Cold Cathode
  • MP7FR Cold Cathode
  • 1F Piezo Diaphragm
  • 3F Mini BA Hot Ion
Technical Information
  • Application Notes
  • Articles
  • Brochures & Flyers
  • Datasheet
  • Electronic Data Sheets (EDS)
  • Infographics
  • Instruction Manuals
  • Videos
Product Lines
  • Tilt Measurement
  • Televac® Vacuum Gauges
  • Ampoules
Product Selection Guide
Product Selection Guide
Product Selection Guide
MX200 Online Order Hub
MX200 Online Order Hub
MX200 Online Order Hub
Web Serial Terminal
Web Serial Terminal
Web Serial Terminal
Vacuum Measurement Converter
Vacuum Measurement Converter
Vacuum Measurement Converter
Televac Calibration and Service
ISO 17025, NIST, and Factory Calibration and Service
Televac Calibration and Service
Contact Us

Contact Us Today

"*" indicates required fields

Name*
Existing customer?*

Vacuum Calibration Services

vacuum calibration services

Quick Reference Table

Description Factory NIST Traceable ISO 17025 Accredited
Electrical verification Yes No No
Vacuum comparison calibration to NIST traceable references No Yes Yes
Reference standard uncertainties included No No Yes
ISO 17025 accredited calibration No No Yes

Submit a Calibration Request



Options for Calibrations

1. ISO 17025 vacuum calibration: The Fredericks Company is ISO/IEC 17025 accredited for vacuum and pressure calibration in the range of 1E-6 Torr to 1000 Torr. Units are vacuum calibrated (on a vacuum stand) in nitrogen gas at various points (gauge dependent) against reference standards traceable to NIST, using systems that are accredited to ISO 17025. This includes incoming (as found) data, outgoing (as left) data after calibration adjustments, and the reference standard uncertainty at each calibration point. A statement of conformity using a simple decision rule is included. The conformity decision is made by comparing the measurement results to the calibration limits, defined by the form downloadable here Televac® Calibration Tolerances, without including measurement uncertainty.

2. NIST traceable vacuum calibration: The Fredericks Company offers NIST traceable calibration, where units are vacuum calibrated (on a vacuum stand) in nitrogen gas at various points (gauge dependent) against reference standards traceable to NIST. This includes incoming (as found) data, outgoing (as left) data after calibration adjustments, but does not include the reference uncertainty at each point (ISO 17025 accredited calibration does include uncertainties).

3. Factory (previously called “standard”) calibration: The Fredericks Company offers factory calibration, where units are electrically verified using electrical equipment only. The verification includes checking that the units provide vacuum readings within a specified tolerance when a specific electrical signal is applied. This is not a vacuum calibration, and does not guarantee that a sensor will read accurately when connected to a controller or active gauge. This is because sensor contamination and sensor to sensor mechanical variability cannot be accounted for with an electrical verification.

Calibration Points

Default vacuum calibration points can be found on our Televac® Calibration Tolerances page. Additional points can be ordered for ISO 17025 accredited and NIST traceable calibrations, and are an additional charge per point. Additional points must be included on your service order request form, they must be shown on our order acknowledgement, and they must be included on your purchase order (if applicable).

Part Numbers

Part Number Description
17025-CAL-1 Default vacuum calibration points for controller and gauge combinations as shown on Televac® Calibration Tolerances, quantity 1 per gauge calibrated
17025-CAL-1-N The same as 17025-CAL-1, but at a reduced price for a new controller or active gauge
17025-CAL-XPT If a point isn’t shown on Televac® Calibration Tolerances, there’s a per point charge for extra points that’s assigned this part number
NIST-CAL-1 Default vacuum calibration points for controller and gauge combinations as shown on Televac® Calibration Tolerances, quantity 1 per gauge calibrated
NIST-CAL-1-N The same as 17025-CAL-1, but at a reduced price for a new controller or active gauge
NIST-CAL-XPT If a point isn’t shown on Televac® Calibration Tolerances, there’s a per point charge for extra points that’s assigned this part number
FACT-CAL-1 Default factory (electrical test) calibration points for controller and gauge combinations as shown on Televac® Calibration Tolerances, quantity 1 per channel or gauge calibrated

Recommended Calibration Intervals

The recommended calibration interval (how often you send your equipment in for calibration) for any type of vacuum calibration is entirely dependent on your specific requirements and quality systems. For example, your facility may adhere to specific standards that require quarterly, semi-annual, or yearly calibrations of vacuum measurement equipment. Or you might expose your vacuum gauges to heavy contamination and you just want to feel confident in the readings. Our default recommendation is a 1 year calibration interval, which will be listed on your calibration certificate and the equipment’s calibration sticker, unless a different interval is requested.

ISO 17025 Calibration More Details

ISO 17025 vacuum calibrations can only be done with electronics like our MX200, MX200 EthernetIP , MM200, MC300, MV2A, Compact 2A, VacuGuard™, or B2A vacuum controllers or MX2A Thermocouple, MX4A Convection, MX7B Cold Cathode, MX7M Cold Cathode, or CC-10 Wide-Range active gauges.

For vacuum controllers, all gauges (sensors) and cables that you’d like calibrated must be returned as a set or purchased new. For active gauges, the cables do not need to be included. For returns, each system will get a unique return number (service order number or RMA number) which can be used to track the system for the return and while it’s at our facility. ISO 17025 accredited calibration pricing is on a per gauge basis, with no distinction in the pricing or order process for the type of controller or gauge.

For example, if you return an MX200 that has 3 gauges that you’d like calibrated, you would order quantity 3 of calibration part number 17025-CAL-1. Similarly, if you needed calibration for an MX4A, you would order quantity 1 of 17025-CAL-1. For ISO 17025 accredited calibrations, calibration options cannot be mixed. For example, if you had an MX200 with 3 channels (stations) you can’t have 2 channels with 17025 calibration and 1 channel with NIST traceable or factory calibration. ISO 17025 accredited calibration certificates can be provided digitally as well as paper copies in the return shipment. ISO 17025 accredited calibration is also available for new systems with the same per gauge approach but at a reduced cost.

NIST Traceable Calibrations More Details

NIST traceable calibrations can only be done with electronics like our MX200, MX200 EthernetIP, MM200, MC300, MV2A, Compact 2A, VacuGuard™, or B2A vacuum controllers or MX2A Thermocouple, MX4A Convection, MX7B Cold Cathode, MX7M Cold Cathode, or CC-10 Wide-Range active gauges. For vacuum controllers, all gauges (sensors) and cables that you’d like calibrated must be returned as a set or purchased new. For active gauges, the cables do not need to be included.

For returns, each system will get a unique return number (service order number or RMA number), which can be used to track the system for the return while it’s at our facility. NIST traceable calibration pricing is on a per gauge basis, with no distinction in the pricing or ordering process for the type of controller or gauge.

For example, if you return an MX200 that has 3 gauges that you’d like calibrated, you would order quantity 3 of calibration part number NIST-CAL-1. Similarly, if you needed calibration for an MX4A, you would order quantity 1 of 17025-CAL-1. For NIST traceable calibrations of multi-channel controllers (MX200, MM200, MC300), calibration options can be mixed with factory calibrations. For example, if you had an MX200 with 3 channels (stations) you can have 2 channels with NIST traceable calibration and 1 channel with factory calibration, or any mix that fits your requirements.

NIST traceable calibration certificates can be provided digitally and as paper copies in the return shipment. NIST traceable calibration is also available for new systems with the same per gauge approach, but at a reduced cost.

Factory Calibrations More Details

Note that factory calibrations are an electrical verification using electrical equipment only (no vacuum comparison). Factory calibrations can only be done with electronics like our MX200, MX200 EthernetIP, MM200, MC300, MV2A, Compact 2A, VacuGuard™, or B2A vacuum controllers or MX2A Thermocouple, MX4A Convection, MX7B Cold Cathode, MX7M Cold Cathode, or CC-10 Wide Range active gauges. For vacuum controllers and active gauges, the gauges (sensors) and cables do not need to be included.

Each system will get a unique return number (service order number or RMA number) which can be used to track the system for the return and while it’s at our facility. Factory calibration pricing is on a per gauge basis, with no distinction in the pricing or order process for the type of controller or gauge.

For example, if you return an MX200 that has channels that you’d like calibrated, you would order quantity 3 of calibration part number FACT-CAL-1. Similarly, if you needed calibration for an MX4A, you would order quantity 1 of FACT-CAL-1. For factory calibrations of multi-channel controllers (MX200, MM200, MC300), NIST traceable calibration can be done on the same return as a NIST traceable calibration (but not an ISO 17025 accredited calibration). For example, if you had an MX200 with 3 channels (stations) you can have 2 channels with NIST traceable calibration and 1 channel with factory calibration, or any mix that fits your requirements.

Factory calibration certificates can be provided digitally and as paper copies in the return shipment. Factory calibration is included in the cost of new units, so there is no additional charge.

Vacuum Calibration Services

We offer comprehensive vacuum calibration services for all our vacuum gauging equipment, including various calibration options to suit your specific needs. Our vacuum calibration services encompass both factory vacuum calibration and NIST traceable vacuum calibration, as well as ISO 17025 Accredited calibrations for all our active gauges and controllers, complemented by passive gauges. Notably, our vacuum calibration services are known for their efficiency, with significantly shorter lead times than competitors. Upon receiving your equipment, our turnaround times typically range from 1 to 2 weeks, and expedited services are also available for those with more urgent requirements. Additionally, if you encounter any issues with your vacuum equipment, we offer the convenience of sending it back to us for evaluation and necessary repairs and service. This comprehensive approach underscores our commitment to providing top-quality calibration services tailored to your specific industry and application needs.

Featured image for Televac calibration and service information
Televac® Calibration and Service Instructions
Televac®️ MX4A Convection Active Vacuum Gauge on a vacuum calibration stand.
Televac® Vacuum Calibration & Service
Employee calibrating Televac®️ vacuum measurement equipment.
Televac® Vacuum Calibration Tolerances
Technical Support
Call
Call +1 215 947 2500
Email
Email Our Sales Team
Quote
Request a Quote
Account
Create an Account
Technical Support
Technical Support
Tilt Measurement Reps
Tilt Measurement Reps
Televac Reps
Televac Reps

Social Media

Fredericks Company on Facebook Fredericks Company on LinkedIn Fredericks Company on TwitterFredericks Company on YouTube

© 2024 The Fredericks Company. All rights reserved. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Contact

The Fredericks Company
2400 Philmont Avenue
Huntingdon Valley, PA 19006

+1 215 947 2500
[email protected]

Products

    • Tilt Measurement
    • Televac® Vacuum Measurement

 

Navigation

  • Homepage
  • Create An Account
  • Request A Quote
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • Privacy Preferences
  • Site Map
Share/Save Your Cart